Lead intensifying screens

To order

 

 

Lead shields are designed to reduce the exposure time and reduce the influence of scattered radiation. They used to uncoated films.

Lead intensifying screens are made from very thin suitable for radiography lead foil, is fixed on the basis of laminated.

The thickness of the lead screens is selected depending on the applied ionizing radiation source and X-ray tube voltage.

Lead shielding made of lead or lead-tin alloy according to GOST 18394-73 and GOST 9559-75.

1,5 – 3
Gain lead screens

Specifications

radiation source screen Thickness, mm
recommended permissible
X-ray machine with a voltage X-ray tube to 100 KB to 0,02 0,02-0,09
X-ray machine with a voltage of the X-ray tube 100 kV to 300 KB 0,05-0,09 0,02-0,09
X-ray machine with a voltage X-ray tube over 300 KB 0,09 0,02-0,09
Tulii – 170 0,09 0,02-0,09
Selenium – 75 0,09-0,20 0,05-0,02
Iridii – 192 0,20-0,30 0,05-0,30
cesium 0,30-0,50 0,09-0,50
Cobalt – 60 0,30-0,50 0,20-0,50