The complex digital radiography "TSIFRAKON"
To orderComplex digital radiography "TSIFRAKON" is intended to detect defects in the welded pipe joint diameter up to 500 mm, and connecting piping and the locking elements by digital radiography.
It reduces the time and cost of control due to a lack of supplies in the form of radiographic film, chemicals and equipment for developing and storing pictures. Electronic images storage base enhances the control of the results. The use of digital radiography reduces the load on the eskpozitsii and staff X-ray.
Software DiSoft
It allows you to receive x-ray image in real time. controls shooting, processes and archives the X-ray images. It provides storage date, time and GPS-coordinates of the shooting place in conjunction with the X-ray image.
Storing images
A digital image is stored in the file format is fully documented DICONDE, corresponding to ASTM E2339-11 standard. This makes it possible to read information, including metadata, using software from different vendors.
IP67
Degree of protection
housing
Features
- wireless transmission of control data via Wi-Fi;
- operating temperature range: from -40 to +45 ° C;
- Software DiSoft;
- 1 class of sensitivity in accordance
to GOST 7512-82; - self-powered battery: 2 o'clock;
- lack of supplies.
Specifications
type of detector | amorphous silicon |
---|---|
scintillator material | CsI / Gadox |
The active region | 146× 146 mm |
image size | 1152× 1152 pixels |
The pixel size | 127 m |
Analog-to-digital conversion | 16 bit |
The minimum exposure time | 30 ms |
The maximum exposure time | 10 min |
Interface | WiFi 802.11g/n/AirMax, USB 3.0 |
dynamic range | 50000:1 |
Working temperature | from -40 to +50 ° C |
storage temperature | from -40 to +70 ° C |
The degree of protection against moisture and dust | IP 67 (short-term immersion to a depth of 1 m) |
Nutrition | Batteries or power supply 110 – 220 AT, 50 – 60 Hz |
Battery | Lithium-ion, 10 Priority, 7.2 AT (working hours 2.5 – 3 o'clock) |
Number of batteries | 8 PC. (4 sets × 2 pieces.) |
Data storage | in non-volatile memory of the detector |
dimensions | 442× 202 × 67 mm |
Weight | 4.9 kg (including battery and protective cover) |